Ultrasonic flow meter (Doppler)
-
Advanced dual-beam Doppler detection technology Based on the dual-beam Doppler principle, water flow velocity and water level are simultaneously measured, and instantaneous flow rate is calculated using a hydraulic model.
-
Precise perception For minute changes in ambient temperature of ±0.2°C, precise digital temperature compensation technology is used for more accurate measurements.
-
Special design for sensor aviation connector The screw-type locking mechanism provides waterproof and corrosion-resistant protection, ensuring reliability, durability, and minimal maintenance.
-
Charging/battery swapping optional design Adaptable to diverse needs under different operating conditions; ultra-low power consumption design for longer battery life; also equipped with a low battery warning function, which intelligently reduces the communication frequency after a low battery warning to extend battery life.
-
Minute-level measurement The communication frequency is intelligently adjusted, automatically changing between 15 minutes, 5 minutes, and 2 minutes based on the water level warning threshold, and the frequency can also be customized.
Communication methods
:NB-IOT
sampling frequency
:2-60min
Reporting frequency
:2~1440min
Configuration method
:Remote parameter setting
Dormant current
:Within 0.2mA
range
:Flow velocity: 0~10m/s, water level: 10m
accuracy
:Flow velocity: 0.001 m/s (within 5 m/s), water level: ±1°%FS
resolution
:Flow velocity: 0.001 m/s, water level: 0.001 m
Operating voltage
:12VDC, 20% deviation
Operating current
:70mA